What Safety Gate found
The authorities in Germany identified that a 30W laser marking machine (1064 nm) failed to meet essential safety requirements. The protective screens did not provide the required Class 1 protection level, allowing reflected or diffused laser radiation to escape the working area.
Why this matters
Laser marking systems often use high-power Class 4 laser sources. Proper enclosures are critical to ensure that radiation is contained, preventing severe eye injuries to operators or bystanders. The failure to meet standards like EN ISO 11553 indicates that the machine's safety integration is insufficient.
What buyers should check
- Ensure the machine comes with a valid EC/EU Declaration of Conformity.
- Verify that the viewing window or enclosure material is certified for the specific laser wavelength (1064 nm in this case).
- Check for the presence of safety interlocks on access panels.
Official source
Safety Gate Reference: A12/01308/22 https://ec.europa.eu/safety-gate-alerts/screen/webReport/alertDetail/10006749
European Commission Safety Gate
Alert A12/01308/22. Open the Commission record to inspect the source information directly.
Open official alert